Module 3 Water Quality Index

Stream Name: COQUITLAM RIVER | Survey Date: 2017-09-22
Chemical Test Result Q-value Weighting Index Value
Temperature Change: 1.00 89.00 X 0.10 = 8.9
Oxygen Saturation: 110.00 95.00 x 0.17 = 16.15
pH (units): 6.80 82.00 x 0.11 = 9.02
Turbidity - JTU: 0.00 100.00 x 0.08 = 8
Turbidity - NTU: x 0.08 = 8
Turbidity (cm): x 0.08 = 0
Total = Water Quality Index (Compare this value to the Water Quality Chart below) 42.07
Water Quality Chart
Good 40-45
Acceptable 30-40
Marginal 20-30
Poor < 20

Survey Results

Stream Name: COQUITLAM RIVER Survey Date: 2017-09-22
Organization Name: Pearson Ecological Project Name: Oxbow side channel
Data Entered by: ZoAnn Survey ID: 269

A) Temperature

Time of Day Air Temp (0o) Water Temp (0o)
am 19.00 14.00
pm 17.00 15.00
Difference in water temperature: 1.00
Site Air Temp(0o) Water Temp(0o)
Upstream:
Downstream:
Difference in water temperature:

B) Dissolved Oxygen

Concentration (mg/l): 11.00
% Saturation: 110.00
Equipment (if not Hach): Hach

C) pH

pH Reading: 6.80
Equipment: hach 5.5-8.5 ra
Nitrites:
Conductivity:
Other one:

Turbidity

Tubdity (JTU): 0.00
Tubdity (NTU):
Tubdity (cm):
Tubdity (cm) greater than (>):
Background Tubdity:
Tubdity increase over background:
Equipment take a dip turbidity bottle and disc