Module 3 Water Quality Index

Stream Name: LAWSON CREEK | Survey Date: 2022-08-06
Chemical Test Result Q-value Weighting Index Value
Temperature Change: 0.00 92.00 X 0.10 = 9.2
Oxygen Saturation: 120.00 90.00 x 0.17 = 15.3
pH (units): 6.80 88.00 x 0.11 = 9.68
Turbidity - JTU: 0.00 0.00 x 0.08 = 0
Turbidity - NTU: 0.00 0.00 x 0.08 = 0
Turbidity (cm): 0.00 70.00 x 0.08 = 5.6
Total = Water Quality Index (Compare this value to the Water Quality Chart below) 39.78
Water Quality Chart
Good 40-45
Acceptable 30-40
Marginal 20-30
Poor < 20

Survey Results

Stream Name: LAWSON CREEK Survey Date: 2022-08-06
Organization Name: West Vancouver streamkeepers Project Name: H2O quality
Data Entered by: leslie Survey ID: 780

A) Temperature

Time of Day Air Temp (0o) Water Temp (0o)
00:00:00 am 0.00 0.00
12:00:00 pm 20.70 15.50
Difference in water temperature: 0.00
Site Air Temp(0o) Water Temp(0o)
Upstream: 0.00 0.00
Downstream: 0.00 0.00
Difference in water temperature: 0.00

B) Dissolved Oxygen

Concentration (mg/l): 12.00
% Saturation: 120.00
Equipment (if not Hach):

C) pH

pH Reading: 6.80
Equipment: hach
Nitrites: 0.00
Conductivity: 0.00
Other one: 0.00

Turbidity

Tubdity (JTU): 0.00
Tubdity (NTU): 0.00
Tubdity (cm): 0.00
Tubdity (cm) greater than (>): 30.00
Background Tubdity: 0.00
Tubdity increase over background: 0.00
Equipment