Module 3 Water Quality Index

Stream Name: BROWNE CREEK | Survey Date: July 16th, 2016
Chemical Test Result Q-value Weighting Index Value
Temperature Change: Temperature 15 88.00 X 0.10 = 8.8
Oxygen Saturation: 100.00 100.00 x 0.17 = 17
pH (units): 6.91 88.00 x 0.11 = 9.68
Turbidity (cm): 60.00 90.00 x 0.08 = 7.2
Total = Water Quality Index (Compare this value to the Water Quality Chart below)
42.68
Water Quality Chart
Good 40-45 Acceptable 30-40 Marginal 20-30 Poor < 20

Survey Results

Stream Name: BROWNE CREEK Survey Date: July 16th, 2016
Organization Name: WaterWealth Project Project Name: WEX
Data Entered by: Ian Stephen Survey ID: 288

Step 1 Temperature

Time of Day Air Temp (0o) Water Temp (0o)
am
pm 21.00 15.00
Difference in water temperature: 15
Q Value:88.00
Site Air Temp(0o) Water Temp(0o)
Upstream:
Downstream:
Difference in water temperature: 15
Q Value:
Step 2 Dissolved Oxygen
Concentration
(mg/l):
10.00
% Saturation: 100.00
Equipment (if not Hach):
Step 3 pH
pH Reading: 6.91
Equipment: Hanna Checker
Nitrites:
Conductivity:
Other one:
Step 4 Turbidity
Tubdity (JTU):
Tubdity (NTU):
Tubdity (cm):
Tubdity (cm) greater than (>): 60.00
Background Tubdity:
Tubdity increase over background:
Equipment 60 cm turbidity tube