Module 3 Water Quality Index

Stream Name: ELK CREEK | Survey Date: July 26th, 2016
Chemical Test Result Q-value Weighting Index Value
Temperature Change: Temperature Not enough data 88.00 X 0.10 = 8.8
Oxygen Saturation: 104.00 97.00 x 0.17 = 16.49
pH (units): 7.10 90.00 x 0.11 = 9.9
Turbidity (cm): 0.00 90.00 x 0.08 = 7.2
Total = Water Quality Index (Compare this value to the Water Quality Chart below)
42.39
Water Quality Chart
Good 40-45 Acceptable 30-40 Marginal 20-30 Poor < 20

Survey Results

Stream Name: ELK CREEK Survey Date: July 26th, 2016
Organization Name: WaterWealth Project Project Name: WEX
Data Entered by: Ian Stephen Survey ID: 291

Step 1 Temperature

Time of Day Air Temp (0o) Water Temp (0o)
Not recorded am Not recorded Not recorded
Not recorded pm Not recorded 16.30
Difference in water temperature: Not enough data
Q Value:88.00
Site Air Temp(0o) Water Temp(0o)
Upstream: Not recorded Not recorded
Downstream: Not recorded Not recorded
Difference in water temperature: Not enough data
Q Value:0.00
Step 2 Dissolved Oxygen
Concentration
(mg/l):
10.28
% Saturation: 104.00
Equipment (if not Hach): Optical O2 Mete
Step 3 pH
pH Reading: 7.10
Equipment: Hach Ph kit
Nitrites: 0.00
Conductivity: 0.00
Other one: 0.00
Step 4 Turbidity
Tubdity (JTU): 0.00
Tubdity (NTU): 0.00
Tubdity (cm): 0.00
Tubdity (cm) greater than (>): 60.00
Background Tubdity: 0.00
Tubdity increase over background: 0.00
Equipment 60 cm turbidity tube