Module 3 Water Quality Index

Stream Name: MANUEL POND | Survey Date: October 23rd, 2018
Chemical Test Result Q-value Weighting Index Value
Temperature Change: Temperature Not enough data 91.00 X 0.10 = 9.1
Oxygen Saturation: 45.00 38.00 x 0.17 = 6.46
pH (units): 7.83 88.00 x 0.11 = 9.68
Turbidity (cm): 0.00 75.00 x 0.08 = 6
Total = Water Quality Index (Compare this value to the Water Quality Chart below)
31.24
Water Quality Chart
Good 40-45 Acceptable 30-40 Marginal 20-30 Poor < 20

Survey Results

Stream Name: MANUEL POND Survey Date: October 23rd, 2018
Organization Name: WaterWealth Project Project Name:
Data Entered by: April Davies Survey ID: 331

Step 1 Temperature

Time of Day Air Temp (0o) Water Temp (0o)
Not recorded am Not recorded Not recorded
Not recorded pm 13.00 10.00
Difference in water temperature: Not enough data
Q Value:91.00
Site Air Temp(0o) Water Temp(0o)
Upstream: Not recorded Not recorded
Downstream: Not recorded Not recorded
Difference in water temperature: Not enough data
Q Value:0.00
Step 2 Dissolved Oxygen
Concentration
(mg/l):
5.00
% Saturation: 45.00
Equipment (if not Hach):
Step 3 pH
pH Reading: 7.83
Equipment: hanna checker
Nitrites: 0.50
Conductivity: 109.00
Other one: 0.00
Step 4 Turbidity
Tubdity (JTU): 0.00
Tubdity (NTU): 0.00
Tubdity (cm): 0.00
Tubdity (cm) greater than (>): 60.00
Background Tubdity: 0.00
Tubdity increase over background: 0.00
Equipment turbity tube