Module 3 Water Quality Index

Stream Name: MOSSOM CREEK | Survey Date: February 28th, 2021
Chemical Test Result Q-value Weighting Index Value
Temperature Change: Temperature Not enough data 98.00 X 0.10 = 9.8
Oxygen Saturation: 102.80 100.00 x 0.17 = 17
pH (units): 7.88 88.00 x 0.11 = 9.68
Turbidity - JTU: 1.40 99.00 x 0.08 = 7.92
Total = Water Quality Index (Compare this value to the Water Quality Chart below)
44.4
Water Quality Chart
Good 40-45 Acceptable 30-40 Marginal 20-30 Poor < 20

Survey Results

Stream Name: MOSSOM CREEK Survey Date: February 28th, 2021
Organization Name: Mossom Creek SEP Project Name: LUSH
Data Entered by: Vicki Guzikowski Survey ID: 620

Step 1 Temperature

Time of Day Air Temp (0o) Water Temp (0o)
10:30:00 am 6.00 5.40
Not recorded pm Not recorded Not recorded
Difference in water temperature: Not enough data
Q Value:98.00
Site Air Temp(0o) Water Temp(0o)
Upstream: Not recorded Not recorded
Downstream: Not recorded Not recorded
Difference in water temperature: Not enough data
Q Value:0.00
Step 2 Dissolved Oxygen
Concentration
(mg/l):
13.00
% Saturation: 102.80
Equipment (if not Hach): Hach and Oxygua
Step 3 pH
pH Reading: 7.88
Equipment: Hanna meter and
Nitrites: 1.80
Conductivity: 103.00
Other one: 0.00
Step 4 Turbidity
Tubdity (JTU): 1.40
Tubdity (NTU): 0.00
Tubdity (cm): 0.00
Tubdity (cm) greater than (>): 0.00
Background Tubdity: 0.00
Tubdity increase over background: 0.00
Equipment Apera turbidimeter