Module 3 Water Quality Index

Stream Name: MOSSOM CREEK | Survey Date: October 3rd, 2021
Chemical Test Result Q-value Weighting Index Value
Temperature Change: Temperature 92.00 X 0.10 = 9.2
Oxygen Saturation: 105.00 98.00 x 0.17 = 16.66
pH (units): 7.61 88.00 x 0.11 = 9.68
Turbidity - JTU: 2.67 98.00 x 0.08 = 7.84
Total = Water Quality Index (Compare this value to the Water Quality Chart below)
43.38
Water Quality Chart
Good 40-45 Acceptable 30-40 Marginal 20-30 Poor < 20

Survey Results

Stream Name: MOSSOM CREEK Survey Date: October 3rd, 2021
Organization Name: Mossom Creek SEP Project Name: LUSH
Data Entered by: Vicki Guzikowski Survey ID: 623

Step 1 Temperature

Time of Day Air Temp (0o) Water Temp (0o)
10:30:00 am 14.00 11.50
13:00:00 pm 999.99 11.50
Difference in water temperature:
Q Value:92.00
Site Air Temp(0o) Water Temp(0o)
Upstream: Not recorded Not recorded
Downstream: Not recorded Not recorded
Difference in water temperature: Not enough data
Q Value:0.00
Step 2 Dissolved Oxygen
Concentration
(mg/l):
12.00
% Saturation: 105.00
Equipment (if not Hach): Hach kit and Ox
Step 3 pH
pH Reading: 7.61
Equipment: Hach Kit and Oa
Nitrites: 1.40
Conductivity: 95.50
Other one: 0.00
Step 4 Turbidity
Tubdity (JTU): 2.67
Tubdity (NTU): 0.00
Tubdity (cm): 0.00
Tubdity (cm) greater than (>): 0.00
Background Tubdity: 0.00
Tubdity increase over background: 0.00
Equipment Apera Turbidimeter